Product Details:
Minimum Order Quantity | 1 per piece |
Use | Industrial |
Brand | Innovative Research Equipments |
Material | Stainless Steel |
Voltage | 230 V |
Frequency | 50 Hz |
Phase | Single Phase |
Power Source | Electric |
This equipment is designed for carrying out the experiment for balancing a rotation mass system. The apparatus consists of a stainless steel shaft fixed in a rectangular frame. A set of four blocks with a clamping arrangement is provided. For static balancing, each block is individually clamped on shaft. For dynamic balancing, a moment polygon is drawn using relative weights and angular and axial position of blocks is determined. The block are clamped on shaft is rotated by a motor to check dynamic balance of the system. The system is provided with angular scale and is suspended with chains for dynamic balancing.
Product Details:
Minimum Order Quantity | 1 Piece |
Capacity | 60 ltr |
Dimensions | Length 500 mm |
Country of Origin | Made in India |
Brand | INNOVATIVE RESEARCH EQIPMENT |
Usage/Application | LAB EXPERIMENT |
Material | Stainless Steel |
Phase | Single Phase |
An Elutriator is vertical tube through which a fluid passes upwardly at a specific velocity while a solid mixture, whose separation is desired, is fed into the top of the column. The large particles, which settle at a velocity higher than that of the rising fluid, are collected at the bottom of the column, and the smaller particles are carried out of the top of the column with the fluid. Several columns of different diameters in series may be used to bring about a further separation. The set up consists of two vertical tubes of different diameter in which water is passed at a controlled velocity. A tank with pump is provided for re-cycled water supply and flow rate is measured by Rota meter and controlled with the help of control valve. The tubes are arranged in a fashion of ascending cross-section area. The particles are introduced through a feed hopper provided at first tube, the smaller particles are carried over in the fluid stream, while the large particles settle against the upward stream. The overflow from the first tube introduced at the bottom of second tube is passed vertically upwards and the overflow from the second tube introduced at the, is passed to drain. The weighed sample originally placed in the first tube of smallest diameter is classified into fractions according to their settling velocities. The fractions are collected in successive tubes by a special arrangement and may be dried and weighed to make analysis.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model | TOM04 |
Cam Shaft Material | Stainless Steel |
Frequency | 50 Hz |
Power Source | Electric |
Voltage | 220 V |
Weights | 1 kg., 500gm, 200 gm & 100gm |
Floor Area | 0.5 m x 1 m |
The setup is a motorized unit consisting of a camshaft driven by a variable speed motor. The free end of the camshaft has a facility to mount the cam easily. The follower is properly guided in gunmetal bushes and the type of follower can be changed according to the cam under test. Graduated circular protractor is fitted co-axial with the shaft and dial gauge fitted on the follower shaft, is used to note the follower displacement for the angle of cam rotation. A spring is used to provide controlling force to the follower system. Weights on the follower shaft can be adjusted as per the requirement. An arrangement is provided to regulate the speed. The apparatus is very useful for testing the cam performance for jump phenomenon during operation and the effect of change of inertia forces on jump action of cam-follower during operation can be observed. Three sets of cams and followers are supplied with the apparatus. These are already hardened to reduce the wear.
With the help of combination of provided cams and followers following experiments can be conducted:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Model | TOM09 |
Automation Type | Automatic |
Phase | Single Phase |
Operating Voltage | 220 V |
Brand | Innovative Research Equipments |
Material | Stainless Steel |
Operating Frequency | 50 Hz |
Floor Area | 1.5 x 2 m3 |
Power | 0.5 KW |
Gear Train is any combination of gear wheels by which motion is transmitted from one shaft to another shaft. In epicyclical gear trains, the axis of shafts on which the gears are mounted may move relative to a fixed axis. It is a motorized unit consisting of a SUN gear mounted on input shaft. Planet gears meshes with the annular gear. These planet gears are mounted on a common arm to which output shaft is fitted. Loading arrangement is provided for loading the system and to measure holding torque
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Capacity | NA |
Type | NA |
Power | 220V AC 1 PHASE |
Application | LAB EXPERIMENT |
Country of Origin | Made in India |
Brand | INNOVATIVE RESEARCH EQUIPMENT |
Model | IRE-UG-11 |
The set-up is designed to study the working of different governors normally used to control the speed. It consists of a main spindle, mounted vertically on the base plate. This spindle is driven by a variable speed Motor which is also mounted vertically on the same base plate. One governor assembly out of four can be mounted on spindle. The spindle speed is controlled by speed control unit. A graduated scale is fitted to the sleeve to measure
the displacement.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | INNOVATIVE RESEARCH EQUIPMENT |
Model | IRE-TOM-01 |
Type | LAB EQUIPMENT |
Power | 230 V AC, Single Phase, 0.5 kW |
Application | LAB EXPERIMENT |
Country of Origin | Made in India |
The apparatus consists of a pad, which can be tilted to the required angle. An endless belt, which moves beneath the pad, carries the oil over its surface from oil bath. When the pad is tilted over the oil film, pressure is developed, the pad is provided with pressure tapings parallel and perpendicular to belt direction. The pressure distribution is measured over a multi tube manometer. The belt is driven by a variable speed motor. The tilting angle and minimum gap between pad and belt can be adjusted and characteristics thus can be studied at various gaps, inclination and relative surface speeds.
Additional Information: